Diode-pumped Solid-State Lasers: LQ-527-12


Diode-pumped Solid-State Lasers: LQ-527-12

  • Diode-pumped solid state laser for retina regeneration
  • Wavelength: 527 nm
  • Short laser pulses of 1.7 ms with up to 1 mJ

Suitable for:

  • Material processing
  • LIBS/RAMAR Spectroscopy
  • LIDAR & WIND LIDAR

Download datasheet

Laser head
Minimum Operation Max. rating
Wavelength(1) [nm] 527
Pulse energy [μJ] 800 1000
Pulse-to-pulse energy stability [%] 95
Pulse width (FWHM) [µs] 1,53 1,67 1,87
Effective pulse duration [µs] 1,55 1,84 2,06
Repetition rate [Hz] 99 100 200
Amplitude variation, typical (Pend/Ppeak) [%] 50
Ripple within one pulse(1) [%] 10
Fluctation of the ratio [%] 10
Output beam centering(2) [mm] 0,4 0,5
Beam quality [M²] 1,5 1,6
Far field beam divergence [mrad] 4 5 6
Mechanics
Operation temperature [ºC] 22 25 28
Stabilization time [s] (TBC) 10 30
Laser beam point stability [µrad] 50
Dimension [mm] 191 x 80 x 56,5
Laser Safety Classification Class 4
Pumping LD not included. Suggested LD features
Wavelength [nm] 804
Current [A] 50
Voltage [V] 2
Pulse width [ms] 800
Fiber core [µm] 200
Fiber NA 0,22
  1. From maximum amplitude
  2. From the center of laser exit window

???? Possible levels of integration for this product are marked in red
Level-of-Integration-Pumped Solid State Lasers_Monocrom

???? Laser Bar Clamping™ Technology

Discover more >> Clamping Technology